With over 20 years of expertise in test chamber manufacturing, LAB1ST specializes in manufacturing customized environmental test chambers, including temperature/humidity chambers, drying ovens, incubators, and more. We offer complete flexibility to meet your specific requirements:
Temperature & Environmental Control:
• Extreme ranges: -80°C to +500°C (customizable)
• Faster temp cycling rates: 5 / 10 / 15 °C/min
• Multi-zone control: Independent temperature zones within one chamber
• Humidity ranges: 10% to 98% RH (with dew point control)
• Vacuum/Positive pressure: For specialized atmospheric simulations
• Gas injection ports: CO₂/O₂/N₂ control for biological needs
Structural & Mechanical Customization:
• Modular sizes: From benchtop (10L) to walk-in (10,000L+)
• Material options: Stainless steel (316L/304), powder-coated steel, or antimicrobial coatings
• Door configurations: Sliding, hinged, or quick-release doors;Transparent panels (heated glass to prevent condensation)
• Internal layouts: Adjustable shelves, rotating platforms, or vibration-isolation mounts; Ports for cables/tubing (sealed or detachable)




600L Test Chamber
- 
Negative pressure design 
- 
Chamber capacity: 600L 
- 
Temperature range: -45℃~150℃ 
- 
Humidity: 20~98% 
- 
Design limit pressure: 20KPa (Inner tank vacuum) 
- 
Voltage: 380V/50HZ 

1500L Temperture Test Room
- 
Double glass observation windows 
- 
Chamber capacity: 1500L 
- 
Temperature range: -20℃~150℃ 
- 
Voltage: 380V 
- 
Shelves: 3pcs 
.jpg)
210L Vertical Test Chamber
- 
Vertical Structure 
- 
Chamber capacity: 210L 
- 
Temperature range: -80℃~150℃ 
- 
Temperature control accuracy: ±0.1℃ 
- 
Avaiable: 100L, 210L, 500L, 1000L 
.jpg)
77 L Environmental Test Chamber
- 
Vertical front - rear structure 
- 
Chamber capacity: 77L 
- 
Instrument located on the door 
- 
Back structure: electrical appliances, water tank, compressor condenser 

3000L Temperature Test Room
- 
With 2 doors and windows 
- 
Chamber capacity: 3m³ 
- 
Temperature range: -20℃~150℃ 
- 
Two opening doors 
.jpg)
87L Customized Test Chamber
- 
4 opening doors in front and rear 
- 
Chamber capacity: 87L 
- 
Temperature range: RT~180℃ 
- 
Four opening doors 
.jpg)
400L Customized Temperature Test Chamber
- 
Customized up-down structure, compressor located on top 
- 
Chamber capacity: 400L 
- 
Temperature range: -50℃~150℃ 

1500L Rapid Temperature Cycling Test Chamber
- 
Heating rate: 21℃/min 
- 
Cooling rate: 0.7~1.5℃/min 
- 
Chamber capacity: 1.5m³ 
- 
Temperature range: -50℃~150℃ 
- 
Actual usage temp: -10℃ 


Custom Ovens

64L Custom Vacuum Drying Oven
- 
Structure: upper-control system, middle-operation chamber, lower-vacuum and water-cooling systems 
- 
Chamber capacity: 77L 
- 
Vacumm degree: 0.1 Pa 

30m³ Glass Initial Pressure Oven
- 
Vacuum range: -0.95 bar to -1.0 bar during glass heating stage. 
- 
Supports both hot and cold vacuum extraction. 
- 
3 independent heating zones 
- 
Temp. range:RT~150℃ 

1000L Vacuum Oven with Recorder
- 
7 independent heating plates 
- 
Temperature range: RT~400℃ 
- 
Ultimate vacuum: 100~0.1KPa 
- 
Total power: 8.1 kw 
- 
Door seal ring with water cooling 

1000L Vacuum Chamber with Jacketed layer
- 
Precision O₂ control + Fast heating + Heavy-duty design 
- 
No shelves | Bottom rack: 350 kg 
- 
RT to 300°C in <50 min 
- 
Vacuum 100 kPa → 0.1 kP 
- 
O₂ control: Auto-adjusts to 50 ppm 

500L Test Oven (Dräger Ventilator Specialized)
- 
For Dräger ventilator 
- 
Chamber capacity: 500L 
- 
Temp. Range: RT~80°C (±0.5°C) 
- 
Humidity: 10~90% RH 

Pharma Stability Testing Chamber
- 
Dual-chamber, Pharmaceutical 
- 
Lighting: 0–6000 LUX (3-level adjustable) + UV sterilization 
- 
magnetic-seal doors, LED lighting 
- 
Temp. Range: 10–65°C with light 
- 
Two opening doors 

150L Small Animal Incubator
- 
Temp. Range: 4–60°C 
- 
Oxygen Control: 0–100% 
- 
Humidity Control: 40–95% RH 
- 
Fast Stabilization: <30 mins to reach set temperature 
- 
APP remote control monitoring 

675L Quartz Tube Vacuum Drying Oven
- 
Structure: Upper: Workspace, Middle: Control system, Lower: Vacuum system 
- 
Vacuum Level: ≤100P 
- 
Temp. range: RT+50–400°C 
- 
Pressure Release: Air/N2 purging 