top of page
flash-chromatography-banner-bg.jpg

Flash Chromatography System

Specially designed and made for lab-scale chromatography experiments and explorations with smart functions and operations, this flash chromatography system is our solution to your purifications.

features.jpg
control-system.jpg

Control System

A smart purification system makes purification easier. The smart flash chromatography system has the built-in feature of separation method recommendation. Even the beginners or non-professional chromatography operators could easily complete the purification task.

tlc-to-gradient.jpg

TLC to Gradient

With the new feature of TLC-to-Gradient built into the control software, the whole process is highly accelerated. The user only needs to input the TLC information and the loading amount of the sample, the software will automatically recommend the proper flash column for the separation.

user-interface.jpg

User Interface

The simple user interface to complete routine- separation. Operated through mobile device, with iconized UI, it is simple enough for the beginner and non-professional to complete routine separation, but also sophisticated enough for the professional or guru to  complete or optimized a complex separation.

hplc-to-gradient.jpg

HPLC to Gradient

The control software can also help you with smart recommendations for reversed-phase separation. Input the analytical HPLC information, including the retention time of the sample, the percentage of solvent B when the specific component is eluted out, the elution gradient will be automatically generated

wireless-operations.png

Wireless Operations

The powerful wireless operations make separations efficiently.

small-column-holder.png

Small Column Holder

Column holder with touchpad enables automatic fixing of flash column.

fraction-collector.png

Fraction Collector

The LCD makes the tracking of tubes containing collected fractions easily.

RFID-technology.png

RFID Technology

Fast indentification of flash column infoirmation based on RFID technology.

FPC-U100

  • Flow range: 1 - 200 ml/min

  • Pressure: 100 PSI (6.9 bar)

  • Pump system: highly accurate and maintenance free ceramic pump

  • Gradients: two solvents, binary

  • Sample loading capcity: 10mg - 33g

  • Column size: 4 - 330g, up to 330kgs with adapters

FPC-U100.png

FPC-U200

  • Flow range: 1 - 200 ml/min

  • Pressure: 200 PSI (13.8 bar)

  • Pump system: highly accurate and maintenance free ceramic pump

  • Gradients: two solvents, binary

  • Sample loading capcity: 10mg - 33g

  • Column size: 4 - 330g, up to 330kgs with adapters

FPC-U200.png

FPC-T100

  • Flow range: 1 - 200 ml/min

  • Pressure: 200 PSI (13.8 bar)

  • Pump system: highly accurate and maintenance free ceramic pump

  • Gradients: four solvents, binary with any combinations of two solvents

  • Sample loading capcity: 10mg - 33g

  • Column size: 4 - 330g, up to 330kgs with adapters

FPC-T200.png
FPC-M1.png

FPC-M1

  • Flow range: 1 - 200 ml/min

  • Pressure: 100 PSI (6.9 bar)

  • Pump system: highly accurate and maintenance free ceramic pump

  • Gradients: four solvents, binary high pressure mixing

  • Sample loading capcity: 10mg - 33g

  • Column size: 4 - 330g, up to 330kgs with adapters

FPC-M2.png

FPC-M2

  • Flow range: 1 - 200 ml/min

  • Pressure: 500 PSI (33.5 bar)

  • Pump system: highly accurate dual piston pump

  • Gradients: four solvents, binary with 3rd solvent as modifier

  • Sample loading capcity: 10mg - 33g

  • Column size: 4 - 330g, up to 330kgs with adapters

FPC-L.png

FPC-L

  • Flow range: 50 - 1000 ml/min

  • Pressure: 150 PSI (10 bar)

  • Pump system: dual valveless metering pump

  • Gradients: four solvents, binary with any combinations of two solvents

  • Sample loading capcity: 10mg - 33g

  • Column size: 4 - 330g, up to 330kgs with adapters

Flash Columns

standard-series-flash-column.jpg
Standard Series

Standard series flash columns are packed with ultra-silica gel using proprietary drying packing technique.

bounded-series-flash-column.jpg
Bonded Series

Bonded series flash columns are manufactured with the same cartridges as the HP series, but are packed with ultra-pure, high quality, high efficiency bonded silica.

e-series-flash-column.jpg
E Series

E series flash columns are manufactured with the same cartridges as the standard series, but are packed with an economical, high-quality silica gel (40-63 µm, 60 Å) or 50-75 µm alumina.

ilok-series-flash-column.jpg
LB-LOK Series

iLOK flash cartridges offer users convenience for manual assembly, allowing for flexible sample loading methods: solid loading and direct liquid injection.

hp-series-flash-column.jpg
HP Series

HP series flash columns are spin-welded and allow for the higher pressure of up to 400 psi. Available adapter facilitates compatibility with any flash system on the market

bio-series-flash-column.jpg
Bio Series

Bio cartridges are available in a wide range of cartridge sizes for any situation (4.5 g, 16 g, 26 g, 38 g, 82 g, 120 g, 225 g, and 320 g), allowing purification from milligrams to grams.

Get an Instant Quote

Thanks for submitting!

Anchor 1
bottom of page