Thermal Shock Chamber
-
Two-zone thermal shock chamber
-
Three-zone thermal shock chamber
Lab1st offers two kinds of thermal shock chambers: two-zone and three zone models.
The chamber simulates rapid temperature changes, which can cause both physical and chemical damage to products. By exposing products to these conditions, manufacturers can optimize their designs and materials based on the test results. Thermal shock chambers are widely used across various industries, including metal, plastic, electronics, aviation, aerospace, new energy, and more.
-
Safe and Secure
-
One-year Warranty
-
Fast Lead Time
-
Excellent Performance
Two-zone thermal shock chamber
TSE Series
The two-zone thermal shock chamber consists of two chambers: a high temperature chamber and a low temperature chamber, with a hanging basket in the middle. During the test, the sample is placed in the hanging basket. When doing a high temperature test, the hanging basket is lifted to the high temperature chamber, and vice versa for a low temperature test.
TSE Series
-
Two kinds of temperature range available: -40℃ to 150℃;-60℃ to 180℃
-
Environmentally friendly: R404a, R23 refrigerants
-
Fast conversion time: the basket can be moved from one chamber to another within 10 seconds.
-
Multifunctional: the single chamber can be used for temperature change tests
Three-zone thermal shock chamber
TSA Series
Three-zone thermal shock chamber has three chambers: a high temperature chamber, a chamber for placing samples, and a low temperature chamber. When testing high temperature, the door high temperature chamber is opened and the door of low temperature chamber is closed. When testing low temperature, the door of high temperature chamber is closed and the door of low temperature chamber is opened. Unlike the two-zone thermal shock chamber, the product does not move during the test.
TSA Series
-
Two kinds of temperature range available: -40℃ to 150℃;-60℃ to 180℃
-
Made of cold-rolled plate and high-temperature electrostatic spraying
-
Control mode: PID+SSR/SCR
-
The data can be exported
Parámetros
Model | TSE-F | TSE-S | TSA-F | TSA-S |
---|---|---|---|---|
Working Volume | 50L, 100L | 50L , 100L | 50L, 100L | 50L, 100L |
High Temp. Exposure Range | 60~150℃ | 60~180℃ | 60~150℃ | 60~180℃ |
Low Temp. Exposure Range | -40~0℃ | -60~0℃ | -40~0℃ | -60~0℃ |
Temp. Fluctuation | ≤±0.5℃ | ≤±0.5℃ | ≤±0.5℃ | ≤±0.5℃ |
Pre-heat Upper Limit | 150℃ | 180℃ | 150℃ | 180℃ |
Pre-cool Upper Limit | -40℃ | -60℃ | -40℃ | -60℃ |
Time | ≤5min | ≤5min | ≤5min | ≤5min |
Type | Two-zone test chamber | Two-zone test chamber | Three-zone test chamber | Three-zone test chamber |